Getting Started
GFK-1742A Chapter 2 Getting Started 2-17
2
48025
ource
ower
To
ine Filter
onnection Strip
Series Amplifier
round Lug
3
2
1
X11-1
Figure 2-11. Connecting the
β
Series Servo Amplifier to the Line Filter and Power Source
Note
You must supply the cable for the connection between the line filter and the
power source. Use 4-conductor, 600V, 60°C (140°F), UL or CSA approved
cable between the line filter and the servo amplifier. The gauge of wire used
for connecting the line filter to the power source must be sized, based on the
size of the circuit breaker between the power source and the line filter and the
number of servos connected to the line filter. The power connectors and
terminals are supplied as part of the amplifier package.
5. Connect the Machine Emergency Stop to the
β
Series Digital Servo
Amplifier
Front Face View)
eries Amplifier
achine E-STOP Device(s)
ormally Closed
24
0
7
0
7
-STOP
mplifier
f First
X5
eries
mplifier
f Second
X5
eries
X5
art of Kit - A02B-0120-K301
X5 Connector
an be connected
p to 6 Amplifiers
n series
X11
Figure 2-12. Connecting the E-STOP to the
β
Series Servo Amplifier
Comments to this Manuals